1-800-570-4277
Morrell Instruments
  • Home
  • Products
    • Upright Microscopes >
      • Eclipse Ei
      • Eclipse Si
      • Eclipse Ci Series
      • Eclipse Ci L Plus
      • Eclipse Ci E
      • Eclipse Ci S
      • Eclipse Ni-U
      • Eclipse Ni-E
    • Inverted Microscopes >
      • Eclipse Ts2
      • Eclipse Ts2R
    • Clinical Instruments >
      • Microscopes
      • Gross Pathology
      • TelePathology >
        • Remote Pathology Consult
        • Slide Scanning Service
      • Assisted Reproductive Technologies
      • Surgical Microscopes
    • Educational Microscopes >
      • Eclipse Ei
      • Eclipse Si
      • SMZ 445 / 460
      • SMZ 745 / 745T
    • Stereomicroscopes >
      • SMZ 445 / 460
      • SMZ 745 / SMZ 745T
      • SMZ 800N
      • SMZ 1270
      • SMZ 18
      • SMZ 25
    • Industrial Instruments >
      • Upright Materials >
        • Eclipse LV150L
        • Eclipse LV-UDM
        • Eclipse LV100 Pol
        • Eclipse LV300N
      • Inverted Material Applications >
        • Eclipse MA100
        • Eclipse MA200
      • Measuring Microscopes >
        • MM200
        • MM400 / MM800
        • V-12B Comparator
      • Video Measuring >
        • iNexiv VMA-2520
        • Nexiv VMZ-R4540
        • Nexiv VMR-H3030
      • Stereo Microscopes >
        • SMZ 445 / 460
        • SMZ745 / SMZ745T
        • SMZ800N
        • SMZ1270
        • SMZ25 / SMZ18
        • AZ100
      • Surface Profiling >
        • BW White Light Interferometry
      • Polarizing Microscopes >
        • Nikon E200 Polarizing Microscope
        • Eclipse Ci-Pol Polarizing Microscope
        • Eclipse LV100-Pol Polarizing Microscope
      • X-Ray >
        • XT V 160
      • Laser Scanning >
        • MMDx
        • Focus Handheld Software
    • Digital Cameras >
      • Nikon DS-1000
      • Nikon DS-Fi3
      • Nikon DS-10
      • Nikon DS-Qi2
      • Andor Zyla sCMOS
    • Imaging Software >
      • NIS Elements Documentation
      • NIS Elements BR
      • NIS Elements AR
    • Optics
    • Light Sources
  • Service
    • Contact Service
    • Equipment Relocation
  • Rentals
    • Movie Props
    • Digital Imaging Services
  • Contact
    • Contact Directory
    • Technical Support
    • Demo Request
    • Quote Request
    • Careers
  • Promotions
  • Support
  • Store
  • About

Picture

Introducing Nikon's most advanced metallurgical microscope.
The Eclipse MA200 is an inverted materials microscope with an innovative design that has been optimized for digital imaging and ergonomic efficiency. The MA200 uses integrated intelligence to automatically combine captured images with data on their observation settings for more comprehensive documentation. Additionally, its new and unique box design allows easy access to the sample on the stage and nosepiece, while making the footprint size one third of the conventional model.


Key Features

Compact, Durable DesignThe compact design employs internal turrets that keep dust off the illumination filters, maintaining bright uniform illumination. Also, the power supply is built-in to save space.

  • Steady box-type main body
  • Out-and-out front-operation
  • High sample visibility
  • Turret-type filter system
  • A / P synchronized mechanism
  • Aperture diaphragms synchronized with B / D changeover
  • Flare prevention mechanism
  • Low power-consumption, but brightness is higher than that of 12V-100W.
  • Dustproof & antistatic body

User-Friendly Operation
  • Controls - All controls are on the front of the instrument for maximum operability.
  • Quick Status Check - The observation position of the objective lens and sample can be checked easily from the microscope's front panel.
  • Analyzer/Polarizer Interlock Mechanism- Links the attachment/release of the analyzer/polarizer.
  • Brightfield/Darkfield Auto-aperture Switching - The field stop and aperture stop automatically open when switched from brightfield to darkfield. When returning to brightfield observation,the previous field and aperture stop settings are reproduced.
  • Flash Prevention Mechanism - Reflection flashes when switching objective lenses are automatically prevented.

World-class CFI60 Optical System

Nikon's world-class CFI60 optics provide clear, high-contrast brightfield images and darkfield images with three times the brightness of conventional models.

Features:

  • Top optical performance in all observation methods
  • Optimized for advanced digital imaging
  • Provide flat and sharp images
  • Lead-free optical system
  • Newly developed metallurgical objectives available
  • Extra low magnification objective 1x, 2.5x with excellent flatness
  • Top quality high magnification objectives (50x, 100x)

Even Illumination
Improved uniformity of illumination delivers clear images, especially for digital imaging.

Wide Field of View

The MA200 features a super-wide field of view with an eyepiece diameter of 25mm. With the combination of the newly developed 1x objective lens, a sample of 25mm diameter can be observed in a single field of view.

Image Analysis

Nikon's DS-U2 Camera Control Unit and NIS-Elements Imaging Software allow the user to perform everything from basic image capture to the measurement, analysis, and management of captured images.

Status Display
Displays information such as objective lens magnification and illumination conditions. The calibration data is automatically changed when the objective magnification is changed. This feature makes the measurement function and other optional software modules such as grain sizing and cast iron analysis module in the NIS-Elements easy to use. 

Quantitative illumination adjustment, which is crucial when acquiring the optimum settings for observation, image capture and especially large image stitching, can be made via PC control.

Stitching
Adjacent images can be put together to create an image with a wide field. It is now possible to capture even more vivid images due to the improved uniformity of the illumination system.

Grain Size Measurement 
Measures grain size and displays results based on JIS and ASTM standards.

Graphite Nodularity Measurement
Measures the graphite nodularity of ground cast iron and displays results based on JIS nd ASTM standards.

Image Capture

DS-L2 Camera Control Unit
Built-in, high-definition, large 8.4-inch XGA LCD screen lets you view & discuss the sample without the need to look in the eyepieces.

Easily Save/Print Data
Captured images can be saved to USB memory or a CF card. In addition to printing directly via a PictBridge-compatible printer, you can save data onto a server over a LAN.

Status Display
Displays information for the objective lens and illumination conditions. Since the correct calibration data is automatically changed when changing magnification, the DS-L2's simple measurement function can be easily employed.

Quantitative illumination adjustment can be made manually by viewing the voltage value. This is crucial when acquiring the optimum settings for observation and image capture.

Energy Saving
The 50W halogen light source realizes the same brightness as the previous 100W light source with only about half the power consumption.

Accessories
  • LV series motorized nosepiece
  • Abundant sample holder
  • DIA pillar
  • INTENSILIGHT fiber illumination system
  • Magnification module



Eclipse MA200 Specifications

Main body
Focusing mechanism
Focusing nosepiece (Fixed stage) Coaxial coarse/fine adjustment knob (torque adjustable)
Coarse adjustment of 4.0 mm per rotation, fine adjustment of 0.2 mm per rotation

Illumination
With flare prevention, Built in UV cut filter
Field diaphragm: dialing continuous variable (centerable), Aperture diaphragm: dialing continuous variable (centerable)
Filter: Double turret (ND16, ND4/GIF, NCB, Additional option available), Polarizing block (Selectable with or without 1/4 Plate)
Fluorescence filter blocks: B/G/V/BV, Built in 12V50W halogen lamp, C-HGFI HG Fiber Illuminator

Light distribution
Eyepiece tube/Back port: 100/0, 55/45

Optics: CFI60 /CFI60-2 system


Observation image: Surface Image

Observation method: Bright/Darkfield/Simple Polarizing/DIC/Epi-Fluorescence

Resolving nosepieces: MA2-NUI5: Bright/Darkfield/DIC 5 position nosepiece, LV-NU5A: Motorized Bright/Darkfield/DIC 5 position nosepiece, D-NID6: Brightfield 6 position nosepiece (Intelligent), D-NI7: Brightfield 7 position nosepiece (Intelligent)

Stage: MA-SR Rectangular 3-plate Stage 50 x 50 mm stroke (includes two stage inserts (ø20mm and 40mm opening) and coaxial control handle on the right side

Dimension: 295 x 215mm, Stroke: 50mm x 50mm (with distance graduation), Standard accessory: ø22 universal specimen holder (with sample clip)

Trinocular eyepiece: Seidentopf, interpupillary distance adjustment 50-75mm

Power input: 100-240V, 50-60Hz

Electrical power consumption: 1.2A 75W

Weight: Approx. 26 kg (depends on combination)

Option: Intermediate magnification
Turret (1x, 1.5x, 2x), Status detection (Output magnification information to main unit)

Scale
MA2-GR Grain Reticle (ASTM E112-63 grain sizing numbers 1 to 8), Grid Reticle(20 lines, 0.5mm)
MA2-MR Scale Reticle (compatible with 5-100x, Read in um, Dialing System)



Download MA200 Brochure
Quote Request

Morrell Instrument Company  |  All rights reserved  |  502 Walt Whitman Road, Melville, NY 11747  |  (631) 423-4800