1-800-570-4277
Morrell Instruments
  • Home
  • Products
    • Upright Microscopes >
      • Eclipse Ei
      • Eclipse Si
      • Eclipse Ci Series
      • Eclipse Ci L Plus
      • Eclipse Ci E
      • Eclipse Ci S
      • Eclipse Ni-U
      • Eclipse Ni-E
    • Inverted Microscopes >
      • Eclipse Ts2
      • Eclipse Ts2R
    • Clinical Instruments >
      • Microscopes
      • Gross Pathology
      • TelePathology >
        • Remote Pathology Consult
        • Slide Scanning Service
      • Assisted Reproductive Technologies
      • Surgical Microscopes
    • Educational Microscopes >
      • Eclipse Ei
      • Eclipse Si
      • SMZ 445 / 460
      • SMZ 745 / 745T
    • Stereomicroscopes >
      • SMZ 445 / 460
      • SMZ 745 / SMZ 745T
      • SMZ 800N
      • SMZ 1270
      • SMZ 18
      • SMZ 25
    • Industrial Instruments >
      • Upright Materials >
        • Eclipse LV150L
        • Eclipse LV-UDM
        • Eclipse LV100 Pol
        • Eclipse LV300N
      • Inverted Material Applications >
        • Eclipse MA100
        • Eclipse MA200
      • Measuring Microscopes >
        • MM200
        • MM400 / MM800
        • V-12B Comparator
      • Video Measuring >
        • iNexiv VMA-2520
        • Nexiv VMZ-R4540
        • Nexiv VMR-H3030
      • Stereo Microscopes >
        • SMZ 445 / 460
        • SMZ745 / SMZ745T
        • SMZ800N
        • SMZ1270
        • SMZ25 / SMZ18
        • AZ100
      • Surface Profiling >
        • BW White Light Interferometry
      • Polarizing Microscopes >
        • Nikon E200 Polarizing Microscope
        • Eclipse Ci-Pol Polarizing Microscope
        • Eclipse LV100-Pol Polarizing Microscope
      • X-Ray >
        • XT V 160
      • Laser Scanning >
        • MMDx
        • Focus Handheld Software
    • Digital Cameras >
      • Nikon DS-1000
      • Nikon DS-Fi3
      • Nikon DS-10
      • Nikon DS-Qi2
      • Andor Zyla sCMOS
    • Imaging Software >
      • NIS Elements Documentation
      • NIS Elements BR
      • NIS Elements AR
    • Optics
    • Light Sources
  • Service
    • Contact Service
    • Equipment Relocation
  • Rentals
    • Microscope Rentals
    • Digital Imaging Services
    • Rental Application
  • Contact
    • Contact Directory
    • Technical Support
    • Demo Request
    • Quote Request
    • Careers
  • Promotions
  • Support
  • Store
  • About

Picture

Nikon's highest precision automated video measuring system is the “Master Reference Measuring System” for your metrology lab. Nikon's highest precision automated vision system, the NEXIV VMR-H3030, has the best specifications, accuracy and repeatability of any NEXIV measuring system, with a minimum readout down to 0.01 µm. It features a 300 x 300 x 150mm stage, TTL Laser height/profile scanning, intelligent pattern recognition and low contrast edge measuring. Perfect when exceptional accuracy is critical, such as calibration of standards and gages, master dies and molds and difficult to measure or ultra-small precision parts.

Key Features

Nikon's Most Advanced Optics
Ultrahigh precision of 0.01µm provides the critical detail necessary for a Master Calibration Instrument. The H3030 features a powerful telecentric 15:1 zoom module with 0.35 NA objective and 50mm free working distance.

Designed and Constructed for Ultra-High Precision

Conceived and designed for the purpose of sub-micron precision measurement, the VMR-H3030 is massive (3x heavier than the equivalent VMR-3020). The stage is constructed of low coefficient of expansion metal with extra heavy duty roller bearing ways. Special high resolution linear encoder scales (with low coefficient of expansion glass scales) provide read-outs that are 10x finer than our other Nexiv Measuring Systems.

Through-the-lens (TTL) Laser Focusing System

Allows users to fully utilize the powerful optics to scan at 1,000 points per second on complex profiles of 3D precision parts and a 15X Telecentric Zoom System that facilitates easy searches at low magnifications.

Unsurpassed Edge Detection

Black and gray portions of a workpiece are digitally classified into 256 levels, then edges are detected and processed based on this classification. This prevents measurement data from being affected by changes in illumination.

When the operator clicks the point to be measured, the system automatically rotates the probes, sets them at the optimum position, and sets the probe size automatically. Desired edges are easily selected by eliminating dust and burrs through a change in the contrast threshold level. Unique algorithms enhance edge detection, even at low magnifications.

Multiple Illumination ChoicesA variety of illumination choices facilitate accurate edge detection in dies and molds. These include:

  • Two LED ring illuminators — 8-sector illumination system consisting of inner (37° oblique angle against Optical Axis) and outer (75° oblique angle) ring illuminators for observation of extremely low-contrast edges that are usually invisible under episcopic illumination.
  • Episcopic illumination — top light
  • Diascopic illumination — bottom light
    Edges previously difficult to capture can be detected with high resolution.

Automeasure Software

Features interactive measurement wizards, which can be customized by each operator for future use. Intelligent search functions eliminate possible measurement errors and a multi-pattern search function automatically corrects part-to-part variation along with deviations in expected edge or feature locations. NEXIV also features a pattern matching measurement system that determines coordinate values for features too difficult to measure in the normal geometric measuring mode.

Rugged Steel Bases

For superior stability in any environment with stage rail designs normally seen on high-end machine tools.

VMR-Z120X Maximum Magnification Model

Offers even greater precision, providing optical magnification to 120x. Ideal for wafer level CSP, wafer bump height and SIP, rerouted masks and masks for MEMS. Other features:

  • High precision stage facilitates accurate measurements for even wider dimensions
  • Enables measurements of top and bottom widths of etched lines
  • Laser AF facilitates measurements of minuscule bump heights
  • Enables evaluation of cross-sectional shapes of bumps and solder balls



Nexiv VMR-H3030 Specifications

Stroke (X x Y x Z): Standard- 300 x 300 x 150mm (11.8 x 11.8 x 5.9 in); with High Magnification module VMR-z120x 300 x 300 x 150mm (11.8 x 11.8 x 5.9 in)

Measuring accuracy (X . Y): Standard U1XY - ; High Magnification U2XY (0.9 + L/300) microns; U1XY (0.6 + L/300) µm

Maximum specimen height: Standard 150; High Magnification 150

Z-axis guide accuracy: (0.9 + L/150) µm

Dimensions (W x D x H) and weight (Main Body): (including table) 1000 x 1230 x 1900 mm (39.4 x 48.4 x 74.8 in); 600kg (1322.8 lb)

Auto focus: (Standard model/High magnification model) Image AF, Laser AF

Field of view: (Standard) 10 x 8 to 1 x 0.8mm; (High magnification model 1) 4 x 3.2 to 0.4 x 0.32mm; (High magnification model 2) 2 x 1.6 to 0.2 x 0.16mm; (High magnification model 3) 1 x 0.8 to 0.1 x 0.08mm

Minimum readout: 0.01 µm

Footprint (D x W): 1500 x 2000 mm (59.1 x 78.7 in)

Maximum workpiece weight: 10kg (22.0 lb)

Dimensions (W x D x H) and weight (Illuminator): 220 x 130 x 360mm (8.7 x 5.1 x 14.2 in); 7kg (15.4 lb)

Zoom Magnification: 5-step zoom for all models- (Standard) 0.75x to 7.5x; (High magnification model 1) 1.875x to 18.75x; (High magnification 2) 3.75x to 37.5x; (High magnification 3) 7.5x to 75x

Power source: AC 100 to 240 V ±10%, 50/60 Hz

Power consumption: Approximately 15A

Camera: B/W CCD or color CCD camera

Host Computer: Main unit PC compatible