1-800-570-4277
Morrell Instruments
  • Home
  • Products
    • Upright Microscopes >
      • Eclipse Ei
      • Eclipse Si
      • Eclipse Ci Series
      • Eclipse Ci L Plus
      • Eclipse Ci E
      • Eclipse Ci S
      • Eclipse Ni-U
      • Eclipse Ni-E
    • Inverted Microscopes >
      • Eclipse Ts2
      • Eclipse Ts2R
    • Clinical Instruments >
      • Microscopes
      • Gross Pathology
      • TelePathology >
        • Remote Pathology Consult
        • Slide Scanning Service
      • Assisted Reproductive Technologies
      • Surgical Microscopes
    • Educational Microscopes >
      • Eclipse Ei
      • Eclipse Si
      • SMZ 445 / 460
      • SMZ 745 / 745T
    • Stereomicroscopes >
      • SMZ 445 / 460
      • SMZ 745 / SMZ 745T
      • SMZ 800N
      • SMZ 1270
      • SMZ 18
      • SMZ 25
    • Industrial Instruments >
      • Upright Materials >
        • Eclipse LV150L
        • Eclipse LV-UDM
        • Eclipse LV100 Pol
        • Eclipse LV300N
      • Inverted Material Applications >
        • Eclipse MA100
        • Eclipse MA200
      • Measuring Microscopes >
        • MM200
        • MM400 / MM800
        • V-12B Comparator
      • Video Measuring >
        • iNexiv VMA-2520
        • Nexiv VMZ-R4540
        • Nexiv VMR-H3030
      • Stereo Microscopes >
        • SMZ 445 / 460
        • SMZ745 / SMZ745T
        • SMZ800N
        • SMZ1270
        • SMZ25 / SMZ18
        • AZ100
      • Surface Profiling >
        • BW White Light Interferometry
      • Polarizing Microscopes >
        • Nikon E200 Polarizing Microscope
        • Eclipse Ci-Pol Polarizing Microscope
        • Eclipse LV100-Pol Polarizing Microscope
      • X-Ray >
        • XT V 160
      • Laser Scanning >
        • MMDx
        • Focus Handheld Software
    • Digital Cameras >
      • Nikon DS-1000
      • Nikon DS-Fi3
      • Nikon DS-10
      • Nikon DS-Qi2
      • Andor Zyla sCMOS
    • Imaging Software >
      • NIS Elements Documentation
      • NIS Elements BR
      • NIS Elements AR
    • Optics
    • Light Sources
  • Service
    • Contact Service
    • Equipment Relocation
  • Rentals
    • Microscope Rentals
    • Digital Imaging Services
    • Rental Application
  • Contact
    • Contact Directory
    • Technical Support
    • Demo Request
    • Quote Request
    • Careers
  • Promotions
  • Support
  • Store
  • About

Picture


Advanced polarized light microscopy under both diascopic and episcopic illumination.
Nikon's Eclipse polarizing microscopes are renowned for their ability to produce brighter, clearer, and higher contrast images. The LV100 POL, available in diascopic and episcopic microscope illumination types, continues this tradition and offers a completely reengineered base for even easier operation. It also features an exclusive high-intensity halogen light source, which delivers brighter images, lower power consumption and less heat generation, thereby reducing the chance of heat-induced focus drift.


Key Features

Diascopic (Transmitted) Light Source
The new high intensity 50W halogen light source incorporates a fly-eye lens design that outputs more light than a 100W lamp. The greater brightness is achieved by optimizing the lamp filament size and optically expanding the size of the light source within the pupil illumination fulfillment.

Lead and Arsenic Free Objective Lenses

The new CFI LU Plan Fluor EPI P objective series uses eco-glass that is manufactured to the same specifications as Nikon's proprietary infinity optics (CFI60) system, but without harmful substances such as lead and arsenic.

30mm Focusing Stroke

The focus stroke has been improved to 30mm, facilitating observation of tall samples.

Reversed Centering Nosepiece

Up to five objectives, ranging from 4x to100x can be mounted to the nosepiece and all five objectives are centerable. The nosepiece is also provided with a DIN compliant compensator slot and it accepts various compensators for advanced quantitative measurements.

Bertrand Lens Incorporated into Design of Intermediate Tube

The Bertrand lens enables both the observation and capture of conoscopic and orthoscopic images. The Bertrand lens is also focusable and centerable.

Rotatable Slider Type Analyzer

The high precision slider-type analyzer located in the intermediate tube is rotatable for a full 360°.

Reduced Focus Drift

Focus drift resulting from light source heat is greatly reduced by virtue of the lower power consumption and heat generated from the new diascopic light source.

Diascopic and Episcopic Polarization

Both Diascopic (transmitted) and Episcopic (reflected) polarization observations are possible by mounting the LV-UEPI universal epi-illuminator.

Episcopic DIC (Differential Interference Contrast)

By mounting the LV-UEPI universal epi-illuminator and optional universal-type nosepiece and DIC accessories including objectives, Episcopic DIC microscopy is possible.

High-Precision Rotating Stage

The stage is large-sized, pre-adjusted and click-stops in 45° increments, making it extremely accurate and easy to rotate. Because the stage is designed to be supported from the bottom of the microscope near the optical axis and incorporates steel cross roller guides, it is twice as stable and durable as conventional stages.

Vibration Resistant Stage

The large sized circular stage is supported near the optical axis and incorporates steal cross roller guides making the stage twice as stable and durable as conventional models. The stage is also extremely accurate, centerable to the optical axis, and provides click-stops at 45° increments.



Eclipse LV100 Pol Specifications

Main Body - Optical System: CFI60 infinity

Main Body Illumination:12V-50W halogen lamp; 12V-50W DC transformer built-in; 

Diascopic/Episcopic illumination changeover switch; Fly-eye lens; NCB11, ND8 filters built-in; 12V-100W type optional (requires external power supply)

Main Body - Focusing: Coaxial coarse/fine focus knob; Focus stroke: 30mm; Coarse: 14mm per rotation; Fine: 0.1mm; Minimum reading: in 1µm increments

Eyepiece:10x (F.O.V. 22mm), CM type with crosshair and micrometer scale

Eyepiece Tube:P-TT Trinocular Tube for polarizing microscopy; P-TB Binocular Tube for polarizing microscopyIntermediate Tube:Built-in focusable Bertrand lens removable from optical path; Switchable Conoscopic/Orthoscopic observations; Analyzer built-in; Plate/compensator slotAnalyzer:360° rotary dial; Minimum reading angle 0.1°

Nosepiece: Reversed centering quintuple nosepiece (detachable); DIN slot

Stage: Top-grade dedicated circular graduated stage. Rotatable 360° horizontally; can be fixed at a specific position. Graduated 360° (in 1° increments); Click stops each 45°. Attachable mechanical stage: 35 x 25mm travel; vernier 0.1mm

Condenser: Dedicated strain-free swing-out type; P Achromat N.A. 0.9

Polarizer: Fixed to the bottom of the condenser holder; Scale

Objectives:CFI P Achromat 4x, 10x, 20x, 40x, 100x, CFI LU Plan Fluor Epi P 5x, 10x, 20x, 50x,100x

Episcopic Illuminator: LV-UEPI Universal Epi-illuminator accommodates a 12V-50W illumination transformer. 12V-100W type optional.(requires external power supply)

Compensators: Standard 1/4 λ & tint plate, quartz wedge or Senarmont compensator can be inserted into intermediate tube slot

Power Consumption: 1.2A/75W

Weight: Approx. 17kg (37.4 lbs) (standard trinocular set)